<?xml version="1.0" encoding="UTF-8" ?><!-- generator=Zoho Sites --><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/"><channel><atom:link href="https://www.gas-detection.net/blogs/Uncategorized/feed" rel="self" type="application/rss+xml"/><title>Tetratech - Blog , Uncategorized</title><description>Tetratech - Blog , Uncategorized</description><link>https://www.gas-detection.net/blogs/Uncategorized</link><lastBuildDate>Fri, 27 Nov 2026 21:10:24 -0800</lastBuildDate><generator>http://zoho.com/sites/</generator><item><title><![CDATA[Bump Testing and Calibration: Keeping Gas Detectors Reliable]]></title><link>https://www.gas-detection.net/blogs/post/gas-detector-bump-test-calibration</link><description><![CDATA[The difference between a bump test and a calibration, how often each is needed for portable and fixed gas detectors, and what a professional calibration service includes.]]></description><content:encoded><![CDATA[
<div class="zpcontent-container blogpost-container "><div data-element-id="elm_oGvt03wTTPykw1fooHSfow" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer"><div data-element-id="elm_oY0aE0epQ1qoPDTTQzyQTg" data-element-type="row" class="zprow zpalign-items- zpjustify-content- "><style type="text/css"></style><div data-element-id="elm_AtFkHgdrR3mdvdXqAA02Sg" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_5lniFqJqSvyuUNSEV0HTQw" data-element-type="text" class="zpelement zpelem-text "><style></style><div class="zptext zptext-align-center " data-editor="true"><p style="text-align:left;">A gas detector that has not been tested is only an assumption. Sensors age, get poisoned by silicones or high concentrations, and drift with temperature and humidity. Bump testing and calibration are how you prove the detector will alarm when it matters.</p><h2 style="text-align:left;">Bump test vs calibration</h2><ul><li style="text-align:left;"><strong>Bump test</strong>: a short exposure to a known gas to check that the sensors respond and the alarms (audible, visual, vibration) work. It does not adjust the readings.</li><li style="text-align:left;"><strong>Calibration</strong>: exposing the detector to certified gas of known concentration and adjusting the reading so it matches. It corrects drift and restores accuracy.</li></ul><h2 style="text-align:left;">How often?</h2><ul><li style="text-align:left;"><strong>Portable detectors</strong>: most manufacturers recommend a bump test before each day's use and a full calibration at regular intervals, typically every 6 months or as the manufacturer specifies, and after any failed bump test.</li><li style="text-align:left;"><strong>Fixed detectors</strong>: functional test and calibration at least every 6 to 12 months depending on the sensor, the gas and the site risk, plus a check of the control panel, relays, sounders, beacons and shut-off valves.</li></ul><h2 style="text-align:left;">What a professional service includes</h2><ul><li style="text-align:left;">Inspection, cleaning and filter replacement.</li><li style="text-align:left;">Calibration with traceable, certified gas cylinders.</li><li style="text-align:left;">Alarm set-point and output checks (4-20 mA, relays, Modbus).</li><li style="text-align:left;">Sensor replacement when the sensor reaches end of life.</li><li style="text-align:left;">A calibration certificate for each instrument, ready for audits.</li></ul><p style="text-align:left;">Tetratech's engineers are manufacturer trained and calibrate portable and fixed gas detectors from Crowcon, Honeywell BW, Sensitron, Tecnocontrol and Sensit, on site or in our workshop. <a href="/calibration-maintenance">See our calibration and maintenance service</a> or <a href="/contact-us">book a visit</a>.</p></div>
</div><div data-element-id="elm_94q4447nSrKnyujOI1NGvQ" data-element-type="button" class="zpelement zpelem-button "><style></style><div class="zpbutton-container zpbutton-align-center"><style type="text/css"></style><a role="button" class="zpbutton-wrapper zpbutton zpbutton-type-primary zpbutton-size-md zpbutton-style-none " href="/contact-us"><span class="zpbutton-content">Book a Calibration</span></a></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Sat, 21 Nov 2026 23:00:53 +0000</pubDate></item><item><title><![CDATA[New IMO Rules for Enclosed Space Entry: Why Your Multi-Gas Detector Now Needs CO2]]></title><link>https://www.gas-detection.net/blogs/post/imo-msc-581-110-enclosed-space-entry-co2-5-gas-detector</link><description><![CDATA[IMO Resolution MSC.581(110) adds carbon dioxide to pre-entry gas testing on ships, with a CO2 limit of 0.5% vol. What changed, what it means for 4-gas detectors, and the Crowcon Gas-Pro 5-gas solution.]]></description><content:encoded><![CDATA[
<div class="zpcontent-container blogpost-container "><div data-element-id="elm_oLMjzmkXReG_iVKeb-5g1w" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer"><div data-element-id="elm_4Nqr8vtzTeOwbpYP5ji65A" data-element-type="row" class="zprow zpalign-items- zpjustify-content- "><style type="text/css"></style><div data-element-id="elm_2XuOZejeSmKsI36Y61uaZw" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_v2eE0vmAQBmUN3zeUGMZNw" data-element-type="text" class="zpelement zpelem-text "><style></style><div class="zptext zptext-align-center " data-editor="true"><p style="text-align:left;">Enclosed spaces on ships, such as cargo holds, ballast and fuel tanks, cofferdams, void spaces and chain lockers, are still one of the leading causes of fatalities at sea. In response, the International Maritime Organization (IMO) adopted <strong>Resolution MSC.581(110)</strong>, the Revised Recommendations for Entering Enclosed Spaces Aboard Ships. Adopted in June 2025, it replaces the earlier Resolution A.1050(27) and applies from December 2025.</p><h2 style="text-align:left;">What changed</h2><ul><li style="text-align:left;"><strong>Carbon dioxide is now a primary hazard.</strong> CO2 is odourless, gives no warning and can cause unconsciousness quickly. It builds up from fermenting or rotting cargoes (grain, timber, fruit, coal), from CO2 fire-extinguishing systems and from inert gas.</li><li style="text-align:left;"><strong>A CO2 limit before entry.</strong> The space should not be entered unless the CO2 reading is below <strong>0.5% by volume (5,000 ppm)</strong>, together with the other limits: oxygen at 20.9% by volume, flammable gas below 1% of the LFL, and toxic gases below 50% of their occupational exposure limit.</li><li style="text-align:left;"><strong>Continuous monitoring.</strong> The atmosphere should be monitored throughout the work, not only before entry, with personal gas detectors carried by the people inside.</li><li style="text-align:left;"><strong>No solo entry.</strong> Single-person entry is not permitted, and ships should keep a register of their enclosed spaces, including connected and adjacent spaces.</li></ul><p style="text-align:left;">The minimum carriage requirement for atmosphere testing instruments remains SOLAS regulation XI-1/7. However, classification societies, flag states and port state control inspectors are using MSC.581(110) as the benchmark, so ship operators are updating their safety management systems and gas detection equipment accordingly.</p><h2 style="text-align:left;">What it means for your gas detectors</h2><p style="text-align:left;">A standard 4-gas detector measures O2, flammable gas (LEL), H2S and CO. It cannot see CO2. To test against the new 0.5% CO2 limit, crews need a detector with an infrared CO2 sensor, which in practice means moving from 4-gas to <strong>5-gas</strong> instruments for enclosed space entry.</p><h2 style="text-align:left;">The solution: Crowcon Gas-Pro 5-gas</h2><p style="text-align:left;">The <a href="/products/crowcon-gas-pro-multi-gas-detector-co-h2s-co2-ch4-o2-pn-gppu1aca-dadbfdiaoc/2480235000007172376">Crowcon Gas-Pro multi-gas detector (CO, H2S, CO2, CH4, O2)</a> measures all five gases in one compact instrument designed for confined space entry:</p><ul><li style="text-align:left;">Detects O2, flammable gas (methane), H2S, CO and CO2 at the same time.</li><li style="text-align:left;">Top-mounted display that the wearer can read without unclipping the detector.</li><li style="text-align:left;">Optional internal pump for pre-entry testing through a sampling line, then diffusion mode for continuous personal monitoring.</li><li style="text-align:left;">Rugged IP65/IP67 housing, with loud audible, visual and vibration alarms.</li><li style="text-align:left;">Supported by the Crowcon I-Test bump test and calibration station.</li></ul><h2 style="text-align:left;">Checklist for ship operators</h2><ul><li style="text-align:left;">Update the enclosed space entry procedure in your SMS with the new CO2 limit.</li><li style="text-align:left;">Check that every portable detector used for entry measures CO2, or upgrade to a 5-gas model.</li><li style="text-align:left;">Make sure detectors are bump tested before use and calibrated at the interval the manufacturer specifies, with certificates on board.</li><li style="text-align:left;">Train crews on the new entry criteria and the ban on single-person entry.</li></ul><p style="text-align:left;">Tetratech is the authorized Crowcon distributor in Egypt. We supply Gas-Pro 5-gas detectors, calibration gas and bump test stations, and calibrate detectors with certificates for audits and port state control. <a href="/products/crowcon-gas-pro-multi-gas-detector-co-h2s-co2-ch4-o2-pn-gppu1aca-dadbfdiaoc/2480235000007172376">View the Gas-Pro 5-gas detector</a> or <a href="/contact-us">request a quote</a>.</p><p style="text-align:left;"><em>Sources: IMO Resolution MSC.581(110); ABS Regulatory News 14/2025; DNV news on the revised IMO recommendations; Crowcon Gas-Pro product information.</em></p></div>
</div><div data-element-id="elm_W9iqM_l4TWWyXlvhftQ64Q" data-element-type="button" class="zpelement zpelem-button "><style></style><div class="zpbutton-container zpbutton-align-center"><style type="text/css"></style><a role="button" class="zpbutton-wrapper zpbutton zpbutton-type-primary zpbutton-size-md zpbutton-style-none " href="https://www.gas-detection.net/products/crowcon-gas-pro-multi-gas-detector-co-h2s-co2-ch4-o2-pn-gppu1aca-dadbfdiaoc/2480235000007172376"><span class="zpbutton-content">Request a Quote for Gas-Pro 5-Gas</span></a></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Sat, 21 Nov 2026 22:59:06 +0000</pubDate></item><item><title><![CDATA[Confined Space Entry: Choosing the Right Portable Gas Detector]]></title><link>https://www.gas-detection.net/blogs/post/confined-space-entry-portable-gas-detector</link><description><![CDATA[The four common gas hazards in confined spaces and how to choose between single-gas, 4-gas and pumped multi-gas detectors from Crowcon and Honeywell BW.]]></description><content:encoded><![CDATA[
<div class="zpcontent-container blogpost-container "><div data-element-id="elm_6VOLSEJRTZi_AQ1RODjtJw" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer"><div data-element-id="elm_-EAHA8ssRkGzimXiOsXRug" data-element-type="row" class="zprow zpalign-items- zpjustify-content- "><style type="text/css"></style><div data-element-id="elm_Yd97ltzmSyCeNw5ly6jdeQ" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_f2VGHQQyQ7WTfd2ZfMsNBg" data-element-type="text" class="zpelement zpelem-text "><style></style><div class="zptext zptext-align-center " data-editor="true"><p style="text-align:left;">Tanks, vessels, sewers, pits, manholes and silos are confined spaces: enclosed, poorly ventilated and often entered only for maintenance. The atmosphere inside can be deadly without any warning signs, so every entry needs gas testing before and during the work.</p><h2 style="text-align:left;">The four common hazards</h2><ul><li style="text-align:left;"><strong>Oxygen (O2)</strong>: deficiency from rusting steel, inert gas purging or biological activity; enrichment from leaking oxygen lines.</li><li style="text-align:left;"><strong>Flammable gas (%LEL)</strong>: methane from sewers and digesters, solvent and fuel vapours.</li><li style="text-align:left;"><strong>Hydrogen sulphide (H2S)</strong>: from sewage, crude oil and sour gas, toxic at low ppm.</li><li style="text-align:left;"><strong>Carbon monoxide (CO)</strong>: from engines, welding and incomplete combustion.</li></ul><h2 style="text-align:left;">Which detector for which job</h2><ul><li style="text-align:left;"><strong>Single-gas detectors</strong> (Crowcon Gasman, Crowcon Clip SGD, Honeywell BW Clip and BW Solo): personal protection where one hazard dominates, such as H2S on an oil site. Maintenance-free models such as Clip SGD and BW Clip run for their full life without calibration.</li><li style="text-align:left;"><strong>4-gas personal monitors</strong> (Crowcon T4, Honeywell GasAlert MicroClip XL and GasAlert Quattro): the standard choice for confined space work, covering O2, LEL, H2S and CO in one instrument.</li><li style="text-align:left;"><strong>Pumped multi-gas monitors</strong> (Crowcon Gas-Pro with pump): needed for pre-entry testing, drawing a sample from the space through a tube before anyone goes in. Gas-Pro measures up to 5 gases and has a dedicated confined space entry mode.</li></ul><h2 style="text-align:left;">Good practice</h2><ul><li style="text-align:left;">Test before entry from outside, at the top, middle and bottom of the space.</li><li style="text-align:left;">Keep monitoring continuously while people are inside.</li><li style="text-align:left;">Bump test the detector before each day's use and calibrate it regularly.</li><li style="text-align:left;">Keep escape equipment and a rescue plan ready.</li></ul><p style="text-align:left;">Tetratech supplies Crowcon and Honeywell BW portable detectors in Egypt, with bump test stations, calibration gas and calibration service. <a href="/collections/confined-space-gas-monitors/2480235000009471973">See confined space monitors</a> or <a href="/contact-us">request a quote</a>.</p><p style="text-align:left;"><em>Sources: Crowcon Gas-Pro, T4, Gasman and Clip SGD product information; Honeywell BW product range.</em></p></div>
</div><div data-element-id="elm_rzPBEHSESRW7_mOa1LEBrw" data-element-type="button" class="zpelement zpelem-button "><style></style><div class="zpbutton-container zpbutton-align-center"><style type="text/css"></style><a role="button" class="zpbutton-wrapper zpbutton zpbutton-type-primary zpbutton-size-md zpbutton-style-none " href="/contact-us"><span class="zpbutton-content">Request a Quote</span></a></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Sat, 21 Nov 2026 22:56:29 +0000</pubDate></item><item><title><![CDATA[Refrigerant Gas Detection in Machinery Rooms: What EN 378 Requires]]></title><link>https://www.gas-detection.net/blogs/post/refrigerant-gas-detection-machinery-rooms-en-378</link><description><![CDATA[Why refrigeration machinery rooms and cold rooms need refrigerant gas detectors, what EN 378-3 asks for, and how to choose detectors for HFC, HFO, NH3 and CO2 systems.]]></description><content:encoded><![CDATA[
<div class="zpcontent-container blogpost-container "><div data-element-id="elm_wtleqVflQRyAzdkykt8MiA" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer"><div data-element-id="elm_G-aiXkpLQbSLhe2lNZqEVA" data-element-type="row" class="zprow zpalign-items- zpjustify-content- "><style type="text/css"></style><div data-element-id="elm_nGtHcX0EQBmkYocZoVPv6A" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_r_GBRQqXSrqF_Zf4G5LzcA" data-element-type="text" class="zpelement zpelem-text "><style></style><div class="zptext zptext-align-center " data-editor="true"><p style="text-align:left;">Chillers, cold stores, supermarkets and HVAC plant rooms hold large charges of refrigerant. A leak can displace oxygen, create a toxic or flammable atmosphere (ammonia, A2L and A3 refrigerants) and cost money in lost refrigerant and downtime. Refrigerant gas detection is therefore both a safety and an environmental requirement.</p><h2 style="text-align:left;">What the standard says</h2><p style="text-align:left;">EN 378-3 states that at least one detector shall be installed in each machinery room, or in the occupied space being considered, where the refrigerant concentration could exceed the practical limit. The detector must trigger an alarm and start the emergency ventilation. Other standards that apply include EN 14624, ISO 5149-3 and the EU F-Gas Regulation.</p><h2 style="text-align:left;">Match the detector to the refrigerant</h2><ul><li style="text-align:left;"><strong>HFC and HFO refrigerants</strong> (R32, R134a, R404A, R410A, R1234yf, R1234ze, R454B and others): infrared or semiconductor sensors.</li><li style="text-align:left;"><strong>Ammonia (R717)</strong>: electrochemical sensors for toxic levels, catalytic for high concentrations in plant rooms.</li><li style="text-align:left;"><strong>CO2 (R744)</strong>: infrared sensors.</li><li style="text-align:left;"><strong>Hydrocarbons (R290 propane)</strong>: flammable gas detectors in %LEL.</li></ul><h2 style="text-align:left;">Where to install</h2><p style="text-align:left;">Most refrigerants are heavier than air, so detectors usually go low, about 20 cm above the floor, close to compressors, valves and joints where leaks start. Ammonia is lighter than air, so its detectors go high. In cold rooms, install the detector in the return air flow.</p><h2 style="text-align:left;">Detectors we supply</h2><ul><li style="text-align:left;"><strong>Sensitron SMART 3-R</strong>: designed for machinery rooms, laboratories and safe areas, with visual and audible alarms, 4-20 mA, RS485 and relay outputs, and compliance with EN 378-3, EN 14624 and ISO 5149-3.</li><li style="text-align:left;"><strong>Sensitron SMART 3 Blizzard</strong>: infrared refrigerant detector for HVAC-R systems and machinery rooms, SIL 2 certified, for gases such as R32, R454B and R410A.</li><li style="text-align:left;"><strong>Sensitron SMART 3G</strong>: ATEX versions for refrigerants in classified areas, including ammonia plant rooms.</li><li style="text-align:left;"><strong>Tecnocontrol TS281 / TS282</strong>: industrial refrigerant and ammonia detectors with 4-20 mA output.</li></ul><p style="text-align:left;">Tetratech supplies, installs and calibrates refrigerant detection systems across Egypt. <a href="/collections/refrigeration-hvac-gas-detection/2480235000009471963">Browse refrigerant detectors</a> or <a href="/contact-us">ask our engineers</a>.</p><p style="text-align:left;"><em>Sources: Sensitron SMART 3-R and SMART 3 Blizzard documentation; EN 378-3:2016 section 9.</em></p></div>
</div><div data-element-id="elm_P3ASPMQCRZK2oMJQrJxotA" data-element-type="button" class="zpelement zpelem-button "><style></style><div class="zpbutton-container zpbutton-align-center"><style type="text/css"></style><a role="button" class="zpbutton-wrapper zpbutton zpbutton-type-primary zpbutton-size-md zpbutton-style-none " href="/contact-us"><span class="zpbutton-content">Request a Quote</span></a></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Sat, 21 Nov 2026 22:54:36 +0000</pubDate></item><item><title><![CDATA[SMART 3G: Choosing ATEX and SIL Fixed Gas Detectors for Oil & Gas]]></title><link>https://www.gas-detection.net/blogs/post/sensitron-smart-3g-atex-sil-gas-detectors-oil-gas</link><description><![CDATA[What to look for in a fixed gas detector for hazardous areas: ATEX/IECEx zones, SIL, sensor technology and outputs, with the Sensitron SMART 3G series as an example.]]></description><content:encoded><![CDATA[
<div class="zpcontent-container blogpost-container "><div data-element-id="elm_49d9nl9VQv2FxnLkJ7TAdg" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer"><div data-element-id="elm_ULP83F1_S8OPzEPy3ZHyGA" data-element-type="row" class="zprow zpalign-items- zpjustify-content- "><style type="text/css"></style><div data-element-id="elm_5ylkkW3HQJmj0Co_tzIPDw" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_tJ0kfMiwSteUM1kj19tNiA" data-element-type="text" class="zpelement zpelem-text "><style></style><div class="zptext zptext-align-center " data-editor="true"><p style="text-align:left;">In oil &amp; gas, petrochemical and chemical plants, a fixed gas detector is a safety device in its own right. It has to work in a classified hazardous area, survive heat, dust and vibration, and give a reliable signal to the fire &amp; gas system. The Sensitron SMART 3G series is a good example of what a modern detector for these sites should offer.</p><h2 style="text-align:left;">1. Hazardous area certification</h2><p style="text-align:left;">Detectors installed in Zone 1 or Zone 2 must be certified for that use. SMART 3G detectors carry ATEX and IECEx certification for Zone 1, with an explosion-proof (Ex db) enclosure. Always check that the gas group and temperature class on the certificate match your area classification.</p><h2 style="text-align:left;">2. Functional safety (SIL)</h2><p style="text-align:left;">Where the detector is part of a safety instrumented function, ask for SIL certification. The SMART 3G series is certified SIL 2 for hardware and SIL 3 for software, which lets designers use it in high-integrity shutdown loops.</p><h2 style="text-align:left;">3. The right sensor for the gas</h2><ul><li style="text-align:left;"><strong>Catalytic (pellistor)</strong>: flammable gases in %LEL.</li><li style="text-align:left;"><strong>Infrared (NDIR)</strong>: hydrocarbons and CO2, immune to sensor poisoning and works in low oxygen.</li><li style="text-align:left;"><strong>Electrochemical</strong>: toxic gases such as H2S, CO, NH3 and Cl2, and oxygen.</li><li style="text-align:left;"><strong>PID</strong>: VOCs such as benzene and toluene at ppm level.</li></ul><p style="text-align:left;">SMART 3G detectors can be fitted with any of these technologies, so one platform covers flammable, toxic, refrigerant and oxygen risks across a site.</p><h2 style="text-align:left;">4. Outputs and maintenance</h2><p style="text-align:left;">Look for a standard 4-20 mA output, optional relays and Modbus RS485, and non-intrusive calibration. SMART 3G-C2 and D2 models allow one-person calibration with a hand-held keypad without opening the enclosure, which saves hot-work permits and time in the field.</p><h2 style="text-align:left;">Which model?</h2><ul><li style="text-align:left;"><strong>SMART 3G-C2</strong>: without display, for detectors read by a control panel.</li><li style="text-align:left;"><strong>SMART 3G-C2-LD</strong>: adds an LED status ring.</li><li style="text-align:left;"><strong>SMART 3G-D2 / D3</strong>: with local display and relays.</li></ul><p style="text-align:left;">Tetratech is the authorized Sensitron distributor in Egypt. We size the system, supply certified detectors and control panels, and provide commissioning and calibration. <a href="/collections/oil-gas-atex-sil-gas-detection/2480235000009471930">See ATEX &amp; SIL detectors</a> or <a href="/contact-us">request a quote</a>.</p><p style="text-align:left;"><em>Sources: Sensitron SMART 3G series documentation and announcements.</em></p></div>
</div><div data-element-id="elm_WEnmg0ifRyKCVBKQU7kuxA" data-element-type="button" class="zpelement zpelem-button "><style></style><div class="zpbutton-container zpbutton-align-center"><style type="text/css"></style><a role="button" class="zpbutton-wrapper zpbutton zpbutton-type-primary zpbutton-size-md zpbutton-style-none " href="/contact-us"><span class="zpbutton-content">Request a Quote</span></a></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Sat, 21 Nov 2026 22:51:24 +0000</pubDate></item><item><title><![CDATA[Car Park CO and NO2 Detection: How to Specify the System (EN 50545-1)]]></title><link>https://www.gas-detection.net/blogs/post/car-park-co-no2-detection-en-50545-1</link><description><![CDATA[How to specify a car park gas detection system in Egypt: which gases to monitor, the EN 50545-1 standard, detector layout, ventilation control and the Tecnocontrol and Sensitron detectors that do the job.]]></description><content:encoded><![CDATA[
<div class="zpcontent-container blogpost-container "><div data-element-id="elm_6hmSCM0dQAajHimIW6GdKA" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer"><div data-element-id="elm_ENpTPRujRaO7TKKgm5sSAA" data-element-type="row" class="zprow zpalign-items- zpjustify-content- "><style type="text/css"></style><div data-element-id="elm_cGvp8cmUQbmEH4Deka1ugg" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_fqEEyFpeQIyMDb25H0x7uw" data-element-type="text" class="zpelement zpelem-text "><style></style><div class="zptext zptext-align-center " data-editor="true"><p style="text-align:left;">Underground and multi-storey car parks collect exhaust gases faster than most building owners expect. Petrol engines release <strong>carbon monoxide (CO)</strong>, diesel engines release <strong>nitrogen dioxide (NO2)</strong>, and vehicles running on LPG add a flammable risk. A fixed gas detection system measures these gases continuously, switches the extraction fans only when they are needed and raises the alarm before the air becomes dangerous.</p><h2 style="text-align:left;">The standard: EN 50545-1</h2><p style="text-align:left;">EN 50545-1 is the European standard for apparatus that detects and measures CO, nitric oxide (NO) and NO2 in car parks and tunnels. It covers both the remote gas sensors and the control unit, and sets construction, performance and test requirements. When you write a specification, ask for detectors and a control unit that comply with EN 50545-1, and ask the supplier for the certificate of the exact model offered.</p><h2 style="text-align:left;">Which gases to monitor</h2><ul><li style="text-align:left;"><strong>CO</strong>: required in almost every car park; the main toxic risk from petrol vehicles.</li><li style="text-align:left;"><strong>NO2</strong>: recommended where diesel vehicles, buses or trucks use the car park.</li><li style="text-align:left;"><strong>LPG or petrol vapour</strong>: where LPG vehicles are allowed, or near fuel dispensing points. LPG is heavier than air, so these detectors are mounted low.</li></ul><h2 style="text-align:left;">How the system works</h2><p style="text-align:left;">Detectors are spread across each level and wired to a control panel. A typical approach uses two thresholds: at the first level the panel starts the ventilation at low speed; at the second it switches the fans to full speed and activates sounders and beacons. Running the fans on demand instead of continuously can cut energy costs significantly.</p><h2 style="text-align:left;">Detectors we supply</h2><ul><li style="text-align:left;"><strong>Tecnocontrol SE237</strong>: compact IP65 detectors for CO, NO2, LPG and petrol vapour, with relay output, for centralised car park alarm systems.</li><li style="text-align:left;"><strong>Tecnocontrol TS255 / TS455</strong>: dual-sensor detectors that measure CO and NO2 (or CO and petrol vapour) in one housing, with 4-20 mA or RS485 output.</li><li style="text-align:left;"><strong>Sensitron SMART 3-NC</strong>: point detector designed for non-classified areas and car parks, IP55, with optional relays and Modbus RS485.</li></ul><h2 style="text-align:left;">Design tips</h2><ul><li style="text-align:left;">Cover the whole floor area, paying attention to ramps, dead corners and areas near entrances and exits.</li><li style="text-align:left;">Mount CO and NO2 detectors at breathing height; mount LPG detectors near the floor.</li><li style="text-align:left;">Plan periodic calibration from day one; electrochemical sensors drift and need regular checks.</li></ul><p style="text-align:left;">Tetratech designs the detector layout, then supplies, installs, commissions and calibrates complete car park systems in Egypt. <a href="/collections/car-park-co-no2-detection/2480235000009471958">Browse car park detectors</a> or <a href="/contact-us">request a quote</a>.</p><p style="text-align:left;"><em>Sources: Tecnocontrol product documentation (SE237, TS255); Sensitron SMART 3-NC datasheet; CENELEC EN 50545-1 scope.</em></p></div>
</div><div data-element-id="elm_gSH6qJUKQMyHHcMZLZbbtA" data-element-type="button" class="zpelement zpelem-button "><style></style><div class="zpbutton-container zpbutton-align-center"><style type="text/css"></style><a role="button" class="zpbutton-wrapper zpbutton zpbutton-type-primary zpbutton-size-md zpbutton-style-none " href="/contact-us"><span class="zpbutton-content">Request a Quote</span></a></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Sat, 21 Nov 2026 17:09:05 +0000</pubDate></item></channel></rss>