0
0

New IMO Rules for Enclosed Space Entry: Why Your Multi-Gas Detector Now Needs CO2

21.11.26 10:59 PM By Mohamed Eltelbany

Enclosed spaces on ships, such as cargo holds, ballast and fuel tanks, cofferdams, void spaces and chain lockers, are still one of the leading causes of fatalities at sea. In response, the International Maritime Organization (IMO) adopted Resolution MSC.581(110), the Revised Recommendations for Entering Enclosed Spaces Aboard Ships. Adopted in June 2025, it replaces the earlier Resolution A.1050(27) and applies from December 2025.

What changed

  • Carbon dioxide is now a primary hazard. CO2 is odourless, gives no warning and can cause unconsciousness quickly. It builds up from fermenting or rotting cargoes (grain, timber, fruit, coal), from CO2 fire-extinguishing systems and from inert gas.
  • A CO2 limit before entry. The space should not be entered unless the CO2 reading is below 0.5% by volume (5,000 ppm), together with the other limits: oxygen at 20.9% by volume, flammable gas below 1% of the LFL, and toxic gases below 50% of their occupational exposure limit.
  • Continuous monitoring. The atmosphere should be monitored throughout the work, not only before entry, with personal gas detectors carried by the people inside.
  • No solo entry. Single-person entry is not permitted, and ships should keep a register of their enclosed spaces, including connected and adjacent spaces.

The minimum carriage requirement for atmosphere testing instruments remains SOLAS regulation XI-1/7. However, classification societies, flag states and port state control inspectors are using MSC.581(110) as the benchmark, so ship operators are updating their safety management systems and gas detection equipment accordingly.

What it means for your gas detectors

A standard 4-gas detector measures O2, flammable gas (LEL), H2S and CO. It cannot see CO2. To test against the new 0.5% CO2 limit, crews need a detector with an infrared CO2 sensor, which in practice means moving from 4-gas to 5-gas instruments for enclosed space entry.

The solution: Crowcon Gas-Pro 5-gas

The Crowcon Gas-Pro multi-gas detector (CO, H2S, CO2, CH4, O2) measures all five gases in one compact instrument designed for confined space entry:

  • Detects O2, flammable gas (methane), H2S, CO and CO2 at the same time.
  • Top-mounted display that the wearer can read without unclipping the detector.
  • Optional internal pump for pre-entry testing through a sampling line, then diffusion mode for continuous personal monitoring.
  • Rugged IP65/IP67 housing, with loud audible, visual and vibration alarms.
  • Supported by the Crowcon I-Test bump test and calibration station.

Checklist for ship operators

  • Update the enclosed space entry procedure in your SMS with the new CO2 limit.
  • Check that every portable detector used for entry measures CO2, or upgrade to a 5-gas model.
  • Make sure detectors are bump tested before use and calibrated at the interval the manufacturer specifies, with certificates on board.
  • Train crews on the new entry criteria and the ban on single-person entry.

Tetratech is the authorized Crowcon distributor in Egypt. We supply Gas-Pro 5-gas detectors, calibration gas and bump test stations, and calibrate detectors with certificates for audits and port state control. View the Gas-Pro 5-gas detector or request a quote.

Sources: IMO Resolution MSC.581(110); ABS Regulatory News 14/2025; DNV news on the revised IMO recommendations; Crowcon Gas-Pro product information.