<?xml version="1.0" encoding="UTF-8" ?><!-- generator=Zoho Sites --><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/"><channel><atom:link href="https://www.gas-detection.net/blogs/tag/sample/feed" rel="self" type="application/rss+xml"/><title>Tetratech - Blog #Sample</title><description>Tetratech - Blog #Sample</description><link>https://www.gas-detection.net/blogs/tag/sample</link><lastBuildDate>Fri, 27 Nov 2026 21:10:24 -0800</lastBuildDate><generator>http://zoho.com/sites/</generator><item><title><![CDATA[Car Park CO and NO2 Detection: How to Specify the System (EN 50545-1)]]></title><link>https://www.gas-detection.net/blogs/post/car-park-co-no2-detection-en-50545-1</link><description><![CDATA[How to specify a car park gas detection system in Egypt: which gases to monitor, the EN 50545-1 standard, detector layout, ventilation control and the Tecnocontrol and Sensitron detectors that do the job.]]></description><content:encoded><![CDATA[
<div class="zpcontent-container blogpost-container "><div data-element-id="elm_6hmSCM0dQAajHimIW6GdKA" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer"><div data-element-id="elm_ENpTPRujRaO7TKKgm5sSAA" data-element-type="row" class="zprow zpalign-items- zpjustify-content- "><style type="text/css"></style><div data-element-id="elm_cGvp8cmUQbmEH4Deka1ugg" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_fqEEyFpeQIyMDb25H0x7uw" data-element-type="text" class="zpelement zpelem-text "><style></style><div class="zptext zptext-align-center " data-editor="true"><p style="text-align:left;">Underground and multi-storey car parks collect exhaust gases faster than most building owners expect. Petrol engines release <strong>carbon monoxide (CO)</strong>, diesel engines release <strong>nitrogen dioxide (NO2)</strong>, and vehicles running on LPG add a flammable risk. A fixed gas detection system measures these gases continuously, switches the extraction fans only when they are needed and raises the alarm before the air becomes dangerous.</p><h2 style="text-align:left;">The standard: EN 50545-1</h2><p style="text-align:left;">EN 50545-1 is the European standard for apparatus that detects and measures CO, nitric oxide (NO) and NO2 in car parks and tunnels. It covers both the remote gas sensors and the control unit, and sets construction, performance and test requirements. When you write a specification, ask for detectors and a control unit that comply with EN 50545-1, and ask the supplier for the certificate of the exact model offered.</p><h2 style="text-align:left;">Which gases to monitor</h2><ul><li style="text-align:left;"><strong>CO</strong>: required in almost every car park; the main toxic risk from petrol vehicles.</li><li style="text-align:left;"><strong>NO2</strong>: recommended where diesel vehicles, buses or trucks use the car park.</li><li style="text-align:left;"><strong>LPG or petrol vapour</strong>: where LPG vehicles are allowed, or near fuel dispensing points. LPG is heavier than air, so these detectors are mounted low.</li></ul><h2 style="text-align:left;">How the system works</h2><p style="text-align:left;">Detectors are spread across each level and wired to a control panel. A typical approach uses two thresholds: at the first level the panel starts the ventilation at low speed; at the second it switches the fans to full speed and activates sounders and beacons. Running the fans on demand instead of continuously can cut energy costs significantly.</p><h2 style="text-align:left;">Detectors we supply</h2><ul><li style="text-align:left;"><strong>Tecnocontrol SE237</strong>: compact IP65 detectors for CO, NO2, LPG and petrol vapour, with relay output, for centralised car park alarm systems.</li><li style="text-align:left;"><strong>Tecnocontrol TS255 / TS455</strong>: dual-sensor detectors that measure CO and NO2 (or CO and petrol vapour) in one housing, with 4-20 mA or RS485 output.</li><li style="text-align:left;"><strong>Sensitron SMART 3-NC</strong>: point detector designed for non-classified areas and car parks, IP55, with optional relays and Modbus RS485.</li></ul><h2 style="text-align:left;">Design tips</h2><ul><li style="text-align:left;">Cover the whole floor area, paying attention to ramps, dead corners and areas near entrances and exits.</li><li style="text-align:left;">Mount CO and NO2 detectors at breathing height; mount LPG detectors near the floor.</li><li style="text-align:left;">Plan periodic calibration from day one; electrochemical sensors drift and need regular checks.</li></ul><p style="text-align:left;">Tetratech designs the detector layout, then supplies, installs, commissions and calibrates complete car park systems in Egypt. <a href="/collections/car-park-co-no2-detection/2480235000009471958">Browse car park detectors</a> or <a href="/contact-us">request a quote</a>.</p><p style="text-align:left;"><em>Sources: Tecnocontrol product documentation (SE237, TS255); Sensitron SMART 3-NC datasheet; CENELEC EN 50545-1 scope.</em></p></div>
</div><div data-element-id="elm_gSH6qJUKQMyHHcMZLZbbtA" data-element-type="button" class="zpelement zpelem-button "><style></style><div class="zpbutton-container zpbutton-align-center"><style type="text/css"></style><a role="button" class="zpbutton-wrapper zpbutton zpbutton-type-primary zpbutton-size-md zpbutton-style-none " href="/contact-us"><span class="zpbutton-content">Request a Quote</span></a></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Sat, 21 Nov 2026 17:09:05 +0000</pubDate></item></channel></rss>