3-Relay card for SMART3 NC / Smart 3g C2 gas detectors. Relay at 12÷24V
RE21-PNA1KONK ATEX CABLE GLAND
0-100 ppm
Adding Relay module to XgardIQ provides Alarm 1, Alarm 2 and Fault SPCO contacts rated 230Vac 5A. Adding R to PN: XIQ-XX-XX-XXX-X-R-X.
Adding HART communications over the 4-20mA signal and via local I.S. pins for HART communicator connection.. Adding H to PN: XIQ-XX-XX-XXX-H-X-X.
"Duct mounting kit - for ducts between 300mm and 3m wide, air-flows from 4 to 20m/s. Note: this accessory can only be used in conjunction with the remote sensor assembly." PN:C01894
XgardIQ remote sensor assembly. 5 meter cable . PN:S012325
XgardIQ remote sensor assembly. 15 metre cable .PN:S012331
Quad gas cylinder for bw 18%O2
3M™ DBI-SALA® Delta™ Vest-Style Climbing Harness Sizes s ,m ,l ,xl
Vest-Style Climbing Harness PN#1102090, Universal, No-tangle design ,Stand-up back D-ring, Front D-ring, Lightweight aluminum quick connect chest and leg straps, Built-in lanyard keepers, Revolving vertical torso buckle, Impact Indicator Protected labels, equipped with 3M™ Connected Safety ID (CSID) Back and front D-rings, quick connect buckle leg straps (size Universal). Specifications Met ANSI A10.32, ANSI Z359.1, OSHA 1910.66, OSHA 1926.502 Torso Buckle Material Zinc Plated Steel Webbing Material Repel™ Polyester Weight (Imperial) 3.8 lb. Weight Capacity 420 lbs. (190 kg) Weight Capacity (Imperial) 420 lb. Weight Capacity (Metric) 190 kg
Gas leak Detector SENSIT Gold G2 EX – TC , LEL / %Vol Part # 911-00000-51 With PPM option and gas leak option and auto log memory and leak search option o The SENSIT Gold G2 ship kit includes: Hard Carrying Case*, Spare Sensor Cap, Wrist Strap, T10 Wrench, Confined Space Probe, Instruction Manual, and 3 Alkaline “C” Batteries.
Smart 3G-C2 Atex Zone 1 Toxic Electrochemical Sensors and Oxygen • Standard 4-20 mA 3 wire output • Optional 1 or 3 relay output • Optional RS485 interface for Modbus communication. • Zero tracking to maintain the zero point steady from possible drifts • Ongoing system self diagnosis • ATEX II 2G Ex db IIC T5 Gb (standard marking) (II 2GD with optional adapter) • ATEX II 2G Ex db [ib] ib IIC T6 Gb for detectors with intrinsically safe protection • SIL 2 HW & SIL3 SW certified
SMART3G-D2 feature: Non-intrusive one man calibration via Hall effect switches 4-digit display and 5 mode status LEDs Multi-color LED light ring Standard 4-20 mA 3 wire output Standard 3 relay output Optional RS485 interface for Modbus communication. Zero tracking to maintain the zero point steady from possible drifts Ongoing system self diagnosis ATEX II 2G Ex db IIC T5 Gb (standard marking) (II2 GD with optional adapter) ATEX II 2G Ex db [ib] IIC T6 Gb for detectors with intrinsically safe protection SIL 2HW & SIL3 SW certified Wide range of sensors and detectable gases Wide range of accessories for installation and maintenance Easy sensor replacement
Sensit PMD2 Standard Kit includes the hard carrying case, rechargeable battery pack, wall transformer with international blades, shoulder strap, pack of filters, pack of blue filters for telescopic survey probe
MULTISCAN 8+16 gas control panel. 8 Analog 4-20 mA inputs and 6 relay outputs on-board the panel. 1 x RS485 type open bus line to connect additional 16 detectors through remote 8- input module or addressable gas detectors daisy chained to the RS485 bus. 6 relay outputs and additional 16 relays via the dedicated STS/16REL card or via remote modules. The panel comes complete with 1 RS232 serial port and 1 USB port for PC connection. Housed in ABS box
Sensit Hand Held laser methan detector
SF6 & Refrigeratent Infra-Red (IR) Sensors• Non-intrusive one man calibration via Hall effect switches • 4-digit display and 5 mode status LEDs • Multi-color LED light ring • Standard 4-20 mA 3 wire output • Standard 3 relay output • Optional RS485 interface for Modbus communication. • Zero tracking to maintain the zero point steady from possible drifts • Ongoing system self diagnosis ATEX II 2G Ex db IIC T5 Gb (standard marking) • ATEX II 2GD Ex db IIC T5 Gb (II2 GD with optional adapter to be specified at the order) • ATEX II 2G Ex db [ib] ib IIC T6 Gb for detectors with intrinsically safe protection • SIL 2HW & SIL3 SW certified
Smart 3G-C2 Atex Zone 1 Flammable Catalytic Sensors • Standard 4-20 mA 3 wire output • Optional 1 or 3 relay output • Optional RS485 interface for Modbus communication. • Zero tracking to maintain the zero point steady from possible drifts • Ongoing system self diagnosis • ATEX II 2G Ex db IIC T5 Gb (standard marking) (II 2GD with optional adapter) • ATEX II 2G Ex db [ib] ib IIC T6 Gb for detectors with intrinsically safe protection • SIL 2 HW & SIL3 SW certified
KANE958, unit with graphic display, wireless, charger, CP2T probe and carry case. Measure and calculate O2, CO, CO2, NO, NOx and SO2 for variety of fuel including light oil (Diesel).
Nova Model 5466K Engine Exhaust Analyzer for O2, CO, HC’s, CO2, NO, NO2 - NDIR infrared detector for CO, CO2, & HCs - electrochemical sensors for O2, CO, NO, NO2 - portable analyzer, suitable for spot-check analysis - ranges : 0 - 25.0 % O2 0 - 5.00 % CO 0 - 20.0 % CO2 0 - 2,000 PPM HC’s (as hexane) 0 - 2,000 PPM NO 0 – 800 PPM NO2 - display : LCD digital touchscreen - output : data logging as CSV file to USB port - operation : re-chargeable battery, DC and AC - power : 220 VAC / 50 Hz. Re-charger and 12VDC cigarette lighter plug supplied loose. - sampling : built-in sample pump, filter and flow meter; condensate bowl; s.s. engine exhaust probe & flexible hose supplied loose. - enclosure : 'K' series suit case style polycarbonate, black. General purpose non-hazardous area use only Standard Probe with S.S. Flex Tip, cool-touch handle & sample hose, for light to medium particulate load, small pre-filter
CO detector series SMART P for car parks sensing element: Electrochemical cell Range: 0-300 ppm Output: serial RS485 to communicate with MULTISCAN++PK control panels Power Supply: 12-24Vdc Compiance with EN 50545-1
CONTROL PANEL MULTISCAN++PK PLASTIC BOX IP65 128I/P MULTISCAN++PK gas control panel. 4 x RS485 type open bus lines or one closed loop. 128 Analog 4-20 mA gas detectors connected through remote 8-input modules or addressable SMART P gas detectors daisy chained to the RS485 control panel's loops and 8 4-20mA inputs onboard the panel. 8 relay output and up to 128 O/C or relay outputs via remote modules. The panel comes complete with 1 parallel port and 1 RS232 serial port for PC connection. Housed in IP65 rated ABS box. Compliance with EN 50545-
SCHEDA 1 RELE' PER/1 RELAY BOARD FOR SMART3
Quad gas cylinder for bw 18%O2
Confined space rescue tripod kit 7” Alumenum tripod , SALA lift II winch 60 ft , ultraloc retrieval SRL 50 ft , with bag and accessories
Gas leak Detector SENSIT Gold G2 EX – TC , LEL / %Vol Part # 911-00000-51 With PPM option and gas leak option and auto log memory and leak search option o The SENSIT Gold G2 ship kit includes: Hard Carrying Case*, Spare Sensor Cap, Wrist Strap, T10 Wrench, Confined Space Probe, Instruction Manual, and 3 Alkaline “C” Batteries. G2 Rechargeable Power Stick Kit Includes: (1) Power Stick, Battery Charger, Battery Sleeve, Charge Port Cover, Wall Adapter, G2 Manual and Battery Charger Manual PN# 871-00076-G2
Gas leak Detector SENSIT Gold G2 EX – TC , LEL / %Vol Part # 911-00000-51 With PPM option and gas leak option and auto log memory and leak search option o The SENSIT Gold G2 ship kit includes: Hard Carrying Case*, Spare Sensor Cap, Wrist Strap, T10 Wrench, Confined Space Probe, Instruction Manual, and 3 Alkaline “C” Batteries.
SMART3-R feature: Standard 4-20 mA, RS485 and 3-relay outputs Multicolour LED ring Internal buzzer for audible warning Ongoing system self-diagnosis Wide range of sensors and detectable gases Optional remote sensor head Easy sensor replacement Standard 12-24 Vdc power supply.
MULTISCAN 8+ gas control panel. 8 Analog 4-20 mA inputs and 6 relay outputs on-board the panel. 1 x RS485 type open bus line to connect additional 8 detectors through remote 8-input module or addressable gas detectors daisy chained to the RS485 bus. 6 relay outputs and additional 16 relays via the dedicated STS/16REL card or via remote modules. The panel comes complete with 1 RS232 serial port and 1 USB port for PC connection. Housed in ABS box
BeSafe Battery storage Gas detector 0-100%LEL H2 , Co 100 PPM STD
SF6 & Refrigeratent Infra-Red (IR) Sensors• Non-intrusive one man calibration via Hall effect switches • 4-digit display and 5 mode status LEDs • Multi-color LED light ring • Standard 4-20 mA 3 wire output • Standard 3 relay output • Optional RS485 interface for Modbus communication. • Zero tracking to maintain the zero point steady from possible drifts • Ongoing system self diagnosis ATEX II 2G Ex db IIC T5 Gb (standard marking) • ATEX II 2GD Ex db IIC T5 Gb (II2 GD with optional adapter to be specified at the order) • ATEX II 2G Ex db [ib] ib IIC T6 Gb for detectors with intrinsically safe protection • SIL 2HW & SIL3 SW certified
Crowcon Detective IQ Pump (P/N: TPACDGB-OCFDZZXAZZZZ) Made in UK Sensor: Oxygen (0-25%), Methane (0-100% LEL), Dual toxic H2S & CO (0-100ppm & 0-1000ppm). English – UK, ATEX / IECEx / INMETRO, Bluetooth and Alarm Passing (Standard), Charger (Multi region power supply)
Gas leak Detector SENSIT Gold G2 EX , LEL PPM Part # 911-00000-01 With PPM option and gas leak option and auto log memory and leak search option o The SENSIT Gold G2 ship kit includes: Soft Carrying Case*, Spare Sensor Cap, Wrist Strap, T10 Wrench, Confined Space Probe, Instruction Manual, and 3 Alkaline “C” Batteries. G2 Rechargeable Power Stick Kit Includes: (1) Power Stick, Battery Charger, Battery Sleeve, Charge Port Cover, Wall Adapter, G2 Manual and Battery Charger Manual PN# 871-00076-G2
SMART 3 NC Gas detector for safe areas For Car Park Applications • Standard 4-20 mA 3 wire output • Optional 3 relay output • Optional RS-485 interface for Modbus communication. • Ongoing system self diagnosis
Constituents.. 1) [S2097ME]Smart 3G-C2, Methane Cat 0-100% LEL - 1 Each 2) [STS1REL]1-Relay card for SMART3G. Relay at 12÷24V - 1 Each
Constituents.. 1) [S2097ME]Smart 3G-C2, Methane Cat 0-100% LEL - 1 Each 2) [STS3REL]3-Relay card for SMART3G. Relay at 12÷24V - 1 Each
Constituents.. 1) [S2097H2]Smart 3G-C2, Hydrogen Cat 0-100% LEL - 1 Each 2) [STS3REL]3-Relay card for SMART3G. Relay at 12÷24V - 1 Each
Constituents.. 1) [S2097H2]Smart 3G-C2, Hydrogen Cat 0-100% LEL - 1 Each 2) [STS1REL]1-Relay card for SMART3G. Relay at 12÷24V - 1 Each