Sensitron Smart 3G-C2-LD Nitric Oxide (NO) Gas Detector, 0-100 ppm, Electrochemical Sensor, ATEX Zone 1 – S2145NO-LD. Applications: Oil & gas facilities and refineries, Laboratories & pharmaceutical facilities, Petrochemical & chemical plants. Supplied, installed and calibrated in Egypt by Tetratech, authorized Sensitron distributor.
Tags:
Product Details
Product Details
Product Details
The Sensitron SMART 3G-C2 is an industrial fixed gas detector in an explosion-proof enclosure for ATEX Zone 1 classified areas. It monitors flammable (%LEL), toxic (ppm), refrigerant gases and oxygen, using catalytic, infrared, electrochemical or PID sensors depending on the gas.
Key features
- Standard 4-20 mA 3 wire output
- Standard 3 relay output
- Standard multi-color LED light ring
- Optional RS485 interface for Modbus communication
- Zero tracking to maintain the zero point steady from possible drifts
- Ongoing system self diagnosis
- ATEX II 2G Ex db IIC T5 Gb (standard marking)
- ATEX II 2GD Ex db IIC T5 Gb (with optional adapter to be specified at the order)
- ATEX II 2G Ex db [ib] ib IIC T6 Gb for detectors with intrinsically safe protection
- SIL 2HW & SIL3 SW certified
Technical specifications
| Brand | Sensitron |
|---|---|
| Manufacturer | Sensitron SRL |
| Model / series | Smart 3G-C2 |
| Part number (SKU) | S2145NO-LD |
| Product type | Fixed Gas Detector |
| Target gas | Nitric Oxide (NO) |
| Measuring range | 0-100 ppm |
| Sensor technology | Electrochemical |
| Certification / protection | ATEX Zone 1 |
| Power supply | 12-24 Vdc |
| Max. power | 5.4 W |
| Outputs | 4-20 mA (3-wire); 3 relays (1 A @ 24 Vdc); optional RS485 Modbus |
| Sensor | Electrochemical cell |
| Expected sensor life | 2-3 years |
| Operating temperature | -30 to +55 °C |
| Operating humidity | 15-90% RH non-condensing |
| Enclosure | Aluminium pressure die-cast, epoxy painted, explosion-proof (Ex d); stainless steel sensor head |
| Dimensions | 145 x 187 x 108 mm |
| Weight | 1900 g |
| Cable entries | 2 x 3/4" NPT |
| IP rating | IP65 |
| ATEX marking | II 2G Ex db IIC T5 Gb (II 2GD Ex db IIC T5 Gb / Ex tb IIIC T100°C Db with optional dust adapter) |
| IECEx marking | Ex db IIC T5 Gb |
| Hazardous area | Zone 1 and Zone 2 (gas); Zone 21/22 with dust adapter |
| SIL | SIL2 hardware / SIL3 software (SIL3 hardware in redundant configuration) |
| Indication | Multi-colour LED light ring |
Applications
- Oil & gas facilities and refineries
- Laboratories & pharmaceutical facilities
- Petrochemical & chemical plants
Supplied, installed and calibrated in Egypt by Tetratech, authorized Sensitron distributor. Request a quote for pricing, availability and technical support.